CROUZET CONTROL
Control relay for monitoring of 3-phase networks with neutral (H3USN) and without neutral (H3US). Adjustable switch at the front for adjustment of correct voltage in 3-phase networks. The switch's position is not registered until the operating voltage is switched on. If the switch position is changed during operation, all LEDs (LED indications) begin to flash but the unit will continue to function normally with the voltage that was set at the most recent power connection. Monitors under-voltage between the phases that can be set between -2 % and -20 % of Un (measurement voltage) and over-voltage that can be set between 2 % and 20 % of Un. Each limit (over-/under-voltage) has its own relay output (R1 Over and R2 Under) and there is an adjustable time delay for each relay output (Tt1 and Tt2), adjustable between 0.3-30 s. H3USN also checks for neutral interruption. Green LED (Un) indicates supply voltage OK. Yellow LED (R) indicates active relay output.
Approvals | CE, CSA, RoHS, UL |
---|---|
Breaking capacity | 5A, 250V AC/DC |
Function | Under/Overvoltage |
IP class connection | IP20 |
IP class housing | IP30 |
Lower limit | -2 - -20% |
Mounting | 35 mm DIN-Rail |
Output | 2x Relay |
Selection of rated voltage | 220, 380, 400, 415, 440, 480V |
Storage temperature max | 70 °C |
Storage temperature min | -40 °C |
---|---|
Supply voltage | 3 x 220-480V AC |
Temperature operational max | 50 °C |
Temperature operational min | -20 °C |
Time delay startup | 0,5 s |
Time delay when exceeding the limit value | 0,3-30s |
Upper limit | 2 - 20% |
Weight | 130 g |
Control relay for monitoring of 3-phase networks with neutral (H3USN) and without neutral (H3US). Adjustable switch at the front for adjustment of correct voltage in 3-phase networks. The switch's position is not registered until the operating voltage is switched on. If the switch position is changed during operation, all LEDs (LED indications) begin to flash but the unit will continue to function normally with the voltage that was set at the most recent power connection. Monitors under-voltage between the phases that can be set between -2 % and -20 % of Un (measurement voltage) and over-voltage that can be set between 2 % and 20 % of Un. Each limit (over-/under-voltage) has its own relay output (R1 Over and R2 Under) and there is an adjustable time delay for each relay output (Tt1 and Tt2), adjustable between 0.3-30 s. H3USN also checks for neutral interruption. Green LED (Un) indicates supply voltage OK. Yellow LED (R) indicates active relay output.
|
|
|
|
|
||
---|---|---|---|---|---|---|
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
Parts | Selection of rated voltage | Supply voltage | Price | ||
---|---|---|---|---|---|
Voltage Monitor Relay H3US 3 x 220-480V
Art:
84873220
Copied
|
220, 380, 400, 415, 440, 480V
|
3 x 220-480V AC
|
| ||
Voltage Monitor Relay H3USN 3 x 120-277V
Art:
84873221
Copied
|
120, 127, 220, 230, 240, 260, 277V
|
3 x 120-277V AC
|
|
Select a variant in the list
If you need any help, you can contact us in one of the following ways: