The 0165 series pressure switch is part of the ATEX range from SUCO for gas zones 1 and 2 offering adjustment while in operation. Pg9 cable gland connector and a maximum voltage of 250 V with a normally open and normally closed contact housed in a 30 A/F alumimium body offering a high pressure resistance. The switch point is very stable even after a long period of time and high load and can come pre-set.
Â
Â
Common applications include oil & gas, mills, foundries, chemical and process industries.
Adjustment range max | 6 bar |
---|---|
Adjustment range min | 1 bar |
Approvals | CSA US, Ex-d |
Contact load max ac | 1 A |
Contact load max dc | 0,25 A |
Deviation max | ±0,5 |
Electrical connection | Embedded 2m cable |
Function | Changeover (SPDT) |
IP class | IP65 |
Material membrane | NBR |
Material of body | Aluminium |
Material of wetted parts | Aluminium, NBR |
Max switching frequency/min | 200 |
---|---|
Pressure max | 200 bar |
Process connection | G1/4 female |
Temperature ambient from | -20 °C |
Temperature ambient to | 80 °C |
Temperature of media from | -20 °C |
Temperature of media to | 80 °C |
Weight | 380 g |
Voltage ac/dc max | 250 V |
Voltage ac/dc min | 10 V |
The 0165 series pressure switch is part of the ATEX range from SUCO for gas zones 1 and 2 offering adjustment while in operation. Pg9 cable gland connector and a maximum voltage of 250 V with a normally open and normally closed contact housed in a 30 A/F alumimium body offering a high pressure resistance. The switch point is very stable even after a long period of time and high load and can come pre-set.
Â
Â
Common applications include oil & gas, mills, foundries, chemical and process industries.
At OEM Automatic, we can supply a series of components for your one project. All under one roof. This case study discusses how we supplied several components for our customer's new electro-pneumatic control box.Â
OEM is pleased to announce a range of hydrogen-approved mechanical pressure switches, by Suco! Today, hydrogen plays a key role in climate-neutral energy generation and storage.
OEM Automatic proudly welcomes the addition of WIKA to its lineup. Wika Force brings a new dimension to the realm of force measurement. The integration of WIKA into the OEM Automatic pressure and flow range represents a significant advancement in force measurement technology!
Georg Fischer is a globally renowned provider of process automation systems and solutions for various industries. Join us as we delve into the advantages and opportunities that this new addition brings to you.
Using hydrogen as a source of energy is an emerging market. ESI have a selected range of pressure sensors that are hydrogen-compatible.
Automated machinery in the process and packaging industries is constantly developing. Find out how we can help to automate process and packaging machinery at OEM.
|
|
|
|
|
||
---|---|---|---|---|---|---|
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
Parts | Adjustment range max | Adjustment range min | Approvals | Deviation max | Material membrane | Material of wetted parts | Pressure max | Temperature of media from | Price | ||
---|---|---|---|---|---|---|---|---|---|---|---|
1..6 bar, G1/4 female, CO, NBR, 2m cable, Ex, Aluminium
Art:
0165448141001
Copied
|
6 bar
|
1 bar
|
CSA US, Ex-d
|
±0,5
|
NBR
|
Aluminium, NBR
|
200 bar
|
-20 °C
|
| ||
1..6 bar, G1/4 female, CO, EPDM, 2m cable, Ex, Aluminium
Art:
0165448142001
Copied
|
6 bar
|
1 bar
|
ATEX, CSA US
|
±0,5
|
EPDM
|
Aluminium, EPDM
|
200 bar
|
-20 °C
|
| ||
1..6 bar, G1/4 female, CO, FKM, 2m cable, Ex, Aluminium
Art:
0165448143001
Copied
|
6 bar
|
1 bar
|
ATEX, CE, CSA US, RoHS II
|
±0,5
|
FKM
|
Aluminium, FKM
|
200 bar
|
-5 °C
|
| ||
5..50 bar, G1/4 female, CO, NBR, 2m cable, Ex, Aluminium
Art:
0165449141001
Copied
|
50 bar
|
5 bar
|
CSA US, Ex-d
|
±3,0
|
NBR
|
Aluminium, NBR
|
200 bar
|
-20 °C
|
| ||
5..50 bar, G1/4 female, CO, EPDM, 2m cable, Ex, Aluminium
Art:
0165449142001
Copied
|
50 bar
|
5 bar
|
ATEX, CE, CSA US, RoHS II
|
±3,0
|
EPDM
|
Aluminium, EPDM
|
200 bar
|
-20 °C
|
| ||
5..50 bar, G1/4 female, CO, FKM, 2m cable, Ex, Aluminium
Art:
0165449143001
Copied
|
50 bar
|
5 bar
|
ATEX, CE, CSA US, RoHS II
|
±3,0
|
FKM
|
Aluminium, FKM
|
200 bar
|
-5 °C
|
| ||
20..100 bar, G1/4 female, CO, NBR, 2m cable, Ex, Aluminium
Art:
0165450141001
Copied
|
100 bar
|
20 bar
|
CSA US, Ex-d
|
±3,0-5,0
|
NBR
|
Aluminium, NBR
|
600 bar
|
-20 °C
|
| ||
25..250 bar, G1/4 female, CO, NBR, 2m cable, Ex, Aluminium
Art:
0165452141001
Copied
|
250 bar
|
25 bar
|
CSA US
|
±5,0-7,0
|
NBR
|
Aluminium, NBR
|
600 bar
|
-20 °C
|
| ||
20..100 bar, G1/4 female, CO, EPDM, 2m cable, Ex, Aluminium
Art:
0165450142001
Copied
|
100 bar
|
20 bar
|
ATEX, CE, CSA US, RoHS II
|
±3,0-5,0
|
EPDM
|
Aluminium, EPDM
|
600 bar
|
-20 °C
|
| ||
20..100 bar, G1/4 female, CO, FKM, 2m cable, Ex, Aluminium
Art:
0165450143001
Copied
|
100 bar
|
20 bar
|
ATEX, CE, CSA US, RoHS II
|
±3,0-5,0
|
FKM
|
Aluminium, FKM
|
600 bar
|
-15 °C
|
| ||
100..400 bar, G1/4 female, CO, NBR, 2m cable, Ex, Aluminium
Art:
0165451141001
Copied
|
400 bar
|
100 bar
|
CSA US, Ex-d
|
±5,0-9,0
|
NBR
|
Aluminium, NBR
|
600 bar
|
-20 °C
|
| ||
100..400 bar, G1/4 female, CO, EPDM, 2m cable, Ex, Aluminium
Art:
0165451142001
Copied
|
400 bar
|
100 bar
|
ATEX, CE, CSA US, RoHS II
|
±5,0-9,0
|
EPDM
|
Aluminium, EPDM
|
600 bar
|
-20 °C
|
| ||
100..400 bar, G1/4 female, CO, FKM, 2m cable, Ex, Aluminium
Art:
0165451143001
Copied
|
400 bar
|
100 bar
|
ATEX, CE, CSA US, RoHS II
|
±5,0-9,0
|
FKM
|
Aluminium, FKM
|
600 bar
|
-15 °C
|
| ||
25..250 bar, G1/4 female, CO, EPDM, 2m cable, Ex, Aluminium
Art:
0165452142001
Copied
|
250 bar
|
25 bar
|
ATEX, CE, CSA US, RoHS II
|
±5,0-7,0
|
EPDM
|
Aluminium, EPDM
|
600 bar
|
-20 °C
|
| ||
25..250 bar, G1/4 female, CO, FKM, 2m cable, Ex, Aluminium
Art:
0165452143001
Copied
|
250 bar
|
25 bar
|
ATEX, CE, CSA US, RoHS II
|
±5,0-7,0
|
FKM
|
Aluminium, FKM
|
600 bar
|
-15 °C
|
|
Select a variant in the list