General data |
|
---|---|
Rated wire cross section | 2,5 mm² |
Colour | Beige |
Fuse max | 18 A |
Fuse size | 5 x 20 mm |
Mounting | TS 35 |
Rated impulse voltage | 6 kV |
Overvoltage category | III |
Contamination degree | 3 |
Approvals | CSA, CSA US, KEMA KUR |
Additional information | with fuse plug |
Dimensions |
|
Length | 68 mm |
Width | 5,1 mm |
Height TS 35/7.5 | 78,7 mm |
Connection data |
|
Connections | 2 |
Number of levels | 1 |
Plug gauge acc. EN 60 947-1 | A3 |
Cross connect channels | 1 |
Number of test pick off options | 2 |
Cross section single wire from | 0,5 mm² |
Cross section single wire to | 4 mm² |
Cross section stranded wire from | 0,5 mm² |
Cross section stranded wire to | 4 mm² |
Cross section stranded with ferrule from | 0,5 mm² |
Cross section stranded with ferrule to | 2,5 mm² |
Rated wire cross section from (AWG) | 12 |
Rated wire cross section to (AWG) | 20 |
Stripping length | 10 mm |
*Invisible Heading* |
|
---|---|
Materials |
|
Insulation material | Polyamide 6.6 |
Flammability class | UL94-V0 |
Operating temperature from | -40 °C |
Operating temperature to | 120 °C |
Approvals |
|
Rated voltage CSA | 300 V |
Rated current CSA | 10 A |
CSA test standard | C22.2 No 158 |
Rated voltage CSAus | 300 V |
Rated current CSAus | 10 A |
CSAus test standard | UL 1059 |
KEMA KEUR test standard | EN 60947-7-1:2009, EN 60947-7-3:2009 |
Additional data |
|
Tariff code | 85369010 |
Country of origin | DE |
Weight | 16 g |
Pack size | 100 |
At OEM Automatic, we can supply a series of components for your one project. All under one roof. This case study discusses how we supplied several components for our customer's new electro-pneumatic control box.Â
To promote constant and reliable performance, as well as a longer life of parts in the vehicle, it is important to consider the right cable protector.
We have now added switch disconnectors to our range! Switch disconnectors contribute to the overall functionality and safety of electrical systems.
LOCC-Box from Lutze is an intelligent current monitoring device that provides reliable protection of DC circuits in a slimline 8.1mm housing.
OEM Automatic has integrated push-in technology into it's product offering for many years now. In this blog post, we'll explore the various benefits of push-in technology and some of the products we offer that make use of this innovation, such as push-in terminals, push-in sockets, and even push-in heaters.
We present Kublers ultimate package: Encoders and Process Displays, which can be used together to create efficient processes.
|
|
|
|
|
||
---|---|---|---|---|---|---|
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
Parts | Rated wire cross section | Colour | Rated voltage IEC | Rated current IEC | Fuse max | Fuse size | Mounting | Rated impulse voltage | Approvals | Additional information | Length | Width | Height TS 35/7.5 | Connections | Number of levels | Plug gauge acc. EN 60 947-1 | Cross connect channels | Number of test pick off options | Cross section single wire from | Cross section single wire to | Cross section stranded wire from | Cross section stranded wire to | Cross section stranded with ferrule from | Cross section stranded with ferrule to | Rated wire cross section from (AWG) | Rated wire cross section to (AWG) | Stripping length | Rated voltage CSA | Rated current CSA | Rated voltage CSAus | Rated current CSAus | KEMA KEUR test standard | Country of origin | Weight | Pack size | Price | ||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ZTRK 2,5/2A/OT BG
Art:
3609.2
Copied
|
2,5 mm²
|
Beige
|
400 V
|
18 A
|
|
|
TS 35
|
6 kV
|
CSA, CSA US, KEMA KUR
|
without function element
|
68 mm
|
5,1 mm
|
39,2 mm
|
2
|
1
|
A3
|
1
|
2
|
0,5 mm²
|
4 mm²
|
0,5 mm²
|
4 mm²
|
0,5 mm²
|
2,5 mm²
|
20
|
12
|
10 mm
|
|
|
|
|
EN 60947-7-1:2009, EN 60947-7-3:2009
|
CZ
|
8,82 g
|
100
|
| ||
ZTRK 2,5/2A/OT OG
Art:
3609.3
Copied
|
2,5 mm²
|
Orange
|
400 V
|
18 A
|
|
|
TS 35
|
6 kV
|
CSA, CSA US, KEMA KUR
|
without function element
|
68 mm
|
5,1 mm
|
39,2 mm
|
2
|
1
|
A3
|
1
|
2
|
0,5 mm²
|
4 mm²
|
0,5 mm²
|
4 mm²
|
0,5 mm²
|
2,5 mm²
|
20
|
12
|
10 mm
|
|
|
|
|
EN 60947-7-1:2009, EN 60947-7-3:2009
|
CZ
|
8,82 g
|
100
|
| ||
ZTRK 2,5/2A/OT BU
Art:
3609.5
Copied
|
2,5 mm²
|
Blue
|
400 V
|
18 A
|
|
|
TS 35
|
6 kV
|
CSA, CSA US, KEMA KUR
|
without function element
|
68 mm
|
5,1 mm
|
39,2 mm
|
2
|
1
|
A3
|
1
|
2
|
0,5 mm²
|
4 mm²
|
0,5 mm²
|
4 mm²
|
0,5 mm²
|
2,5 mm²
|
20
|
12
|
10 mm
|
|
|
|
|
EN 60947-7-1:2009, EN 60947-7-3:2009
|
CZ
|
8,82 g
|
100
|
| ||
ZTRK 2,5/3A/OT BG
Art:
3610.2
Copied
|
2,5 mm²
|
Beige
|
400 V
|
18 A
|
|
|
TS 35
|
6 kV
|
CSA, CSA US, KEMA KUR
|
without function element
|
80,2 mm
|
5,1 mm
|
39,2 mm
|
3
|
1
|
A3
|
1
|
2
|
0,5 mm²
|
4 mm²
|
0,5 mm²
|
4 mm²
|
0,5 mm²
|
2,5 mm²
|
20
|
12
|
10 mm
|
|
|
|
|
EN 60947-7-1:2009, EN 60947-7-3:2009
|
CZ
|
10,99 g
|
100
|
| ||
ZTRK 2,5/3A/OT OG
Art:
3610.3
Copied
|
2,5 mm²
|
Orange
|
400 V
|
18 A
|
|
|
TS 35
|
6 kV
|
CSA, CSA US, KEMA KUR
|
without function element
|
80,2 mm
|
5,1 mm
|
39,2 mm
|
3
|
1
|
A3
|
1
|
2
|
0,5 mm²
|
4 mm²
|
0,5 mm²
|
4 mm²
|
0,5 mm²
|
2,5 mm²
|
20
|
12
|
10 mm
|
|
|
|
|
EN 60947-7-1:2009, EN 60947-7-3:2009
|
CZ
|
10,99 g
|
100
|
| ||
ZTRK 2,5/3A/OT BU
Art:
3610.5
Copied
|
2,5 mm²
|
Blue
|
400 V
|
18 A
|
|
|
TS 35
|
6 kV
|
CSA, CSA US, KEMA KUR
|
without function element
|
80,2 mm
|
5,1 mm
|
39,2 mm
|
3
|
1
|
A3
|
1
|
2
|
0,5 mm²
|
4 mm²
|
0,5 mm²
|
4 mm²
|
0,5 mm²
|
2,5 mm²
|
20
|
12
|
10 mm
|
|
|
|
|
EN 60947-7-1:2009, EN 60947-7-3:2009
|
CZ
|
10,99 g
|
100
|
| ||
ZTRK 2,5/4A/OT BG
Art:
3611.2
Copied
|
2,5 mm²
|
Beige
|
400 V
|
18 A
|
|
|
TS 35
|
6 kV
|
CSA, CSA US, KEMA KUR
|
without function element
|
92,4 mm
|
5,1 mm
|
39,2 mm
|
4
|
1
|
A3
|
1
|
2
|
0,5 mm²
|
4 mm²
|
0,5 mm²
|
4 mm²
|
0,5 mm²
|
2,5 mm²
|
20
|
12
|
10 mm
|
|
|
|
|
EN 60947-7-1:2009, EN 60947-7-3:2009
|
CZ
|
12,66 g
|
100
|
| ||
ZTRK 2,5/4A/OT OG
Art:
3611.3
Copied
|
2,5 mm²
|
Orange
|
400 V
|
18 A
|
|
|
TS 35
|
6 kV
|
CSA, CSA US, KEMA KUR
|
without function element
|
92,4 mm
|
5,1 mm
|
39,2 mm
|
4
|
1
|
A3
|
1
|
2
|
0,5 mm²
|
4 mm²
|
0,5 mm²
|
4 mm²
|
0,5 mm²
|
2,5 mm²
|
20
|
12
|
10 mm
|
|
|
|
|
EN 60947-7-1:2009, EN 60947-7-3:2009
|
CZ
|
12,66 g
|
100
|
| ||
ZTRK 2,5/4A/OT BU
Art:
3611.5
Copied
|
2,5 mm²
|
Blue
|
400 V
|
18 A
|
|
|
TS 35
|
6 kV
|
CSA, CSA US, KEMA KUR
|
without function element
|
92,4 mm
|
5,1 mm
|
39,2 mm
|
4
|
1
|
A3
|
1
|
2
|
0,5 mm²
|
4 mm²
|
0,5 mm²
|
4 mm²
|
0,5 mm²
|
2,5 mm²
|
20
|
12
|
10 mm
|
|
|
|
|
EN 60947-7-1:2009, EN 60947-7-3:2009
|
CZ
|
12,66 g
|
100
|
| ||
ZTRK 2,5/2A/ZS BG
Art:
3616.2
Copied
|
2,5 mm²
|
Beige
|
|
|
18 A
|
5 x 20 mm
|
TS 35
|
6 kV
|
CSA, CSA US, KEMA KUR
|
with fuse plug
|
68 mm
|
5,1 mm
|
78,7 mm
|
2
|
1
|
A3
|
1
|
2
|
0,5 mm²
|
4 mm²
|
0,5 mm²
|
4 mm²
|
0,5 mm²
|
2,5 mm²
|
12
|
20
|
10 mm
|
300 V
|
10 A
|
300 V
|
10 A
|
EN 60947-7-1:2009, EN 60947-7-3:2009
|
DE
|
16 g
|
100
|
| ||
ZTRK 2,5/2A/ZS BU
Art:
3616.5
Copied
|
2,5 mm²
|
Blue
|
|
|
18 A
|
5 x 20 mm
|
TS 35
|
6 kV
|
CSA, CSA US, KEMA KUR
|
with fuse plug
|
68 mm
|
5,1 mm
|
78,7 mm
|
2
|
1
|
A3
|
1
|
2
|
0,5 mm²
|
4 mm²
|
0,5 mm²
|
4 mm²
|
0,5 mm²
|
2,5 mm²
|
12
|
20
|
10 mm
|
300 V
|
10 A
|
300 V
|
10 A
|
EN 60947-7-1:2009, EN 60947-7-3:2009
|
DE
|
16 g
|
100
|
| ||
ZTRK 2,5/2A/ZS 36 BG
Art:
3617.2
Copied
|
2,5 mm²
|
Beige
|
|
|
18 A
|
5 x 20 mm
|
TS 35
|
6 kV
|
CSA, CSA US, KEMA KUR
|
with fuse plug + status display 10-36V
|
68 mm
|
5,1 mm
|
78,7 mm
|
2
|
1
|
A3
|
1
|
2
|
0,5 mm²
|
4 mm²
|
0,5 mm²
|
4 mm²
|
0,5 mm²
|
2,5 mm²
|
12
|
20
|
10 mm
|
300 V
|
10 A
|
300 V
|
10 A
|
EN 60947-7-1:2009, EN 60947-7-3:2009
|
DE
|
16 g
|
100
|
| ||
ZTRK 2,5/2A/ZS 70 BG
Art:
3618.2
Copied
|
2,5 mm²
|
Beige
|
|
|
18 A
|
5 x 20 mm
|
TS 35
|
6 kV
|
CSA, CSA US, KEMA KUR
|
with fuse plug + status display 35-70V
|
68 mm
|
5,1 mm
|
78,7 mm
|
2
|
1
|
A3
|
1
|
2
|
0,5 mm²
|
4 mm²
|
0,5 mm²
|
4 mm²
|
0,5 mm²
|
2,5 mm²
|
12
|
20
|
10 mm
|
300 V
|
10 A
|
300 V
|
10 A
|
EN 60947-7-1:2009, EN 60947-7-3:2009
|
DE
|
16 g
|
100
|
| ||
ZTRK 2,5/2A/ZS 150 BG
Art:
3619.2
Copied
|
2,5 mm²
|
Beige
|
|
|
18 A
|
5 x 20 mm
|
TS 35
|
6 kV
|
CSA, CSA US, KEMA KUR
|
with fuse plug + status display 60-150V
|
68 mm
|
5,1 mm
|
78,7 mm
|
2
|
1
|
A3
|
1
|
2
|
0,5 mm²
|
4 mm²
|
0,5 mm²
|
4 mm²
|
0,5 mm²
|
2,5 mm²
|
12
|
20
|
10 mm
|
300 V
|
10 A
|
300 V
|
10 A
|
EN 60947-7-1:2009, EN 60947-7-3:2009
|
DE
|
16 g
|
100
|
| ||
ZTRK 2,5/2A/ZS 250 BG
Art:
3620.2
Copied
|
2,5 mm²
|
Beige
|
|
|
18 A
|
5 x 20 mm
|
TS 35
|
6 kV
|
CSA, CSA US, KEMA KUR
|
with fuse plug + status display 140-250V
|
68 mm
|
5,1 mm
|
78,7 mm
|
2
|
1
|
A3
|
1
|
2
|
0,5 mm²
|
4 mm²
|
0,5 mm²
|
4 mm²
|
0,5 mm²
|
2,5 mm²
|
12
|
20
|
10 mm
|
300 V
|
10 A
|
300 V
|
10 A
|
EN 60947-7-1:2009, EN 60947-7-3:2009
|
DE
|
16 g
|
100
|
| ||
ZTRK 2,5/3A/ZS BG
Art:
3621.2
Copied
|
2,5 mm²
|
Beige
|
|
|
18 A
|
5 x 20 mm
|
TS 35
|
6 kV
|
CSA, CSA US, KEMA KUR
|
with fuse plug
|
80,2 mm
|
5,1 mm
|
78,7 mm
|
3
|
1
|
A3
|
1
|
2
|
0,5 mm²
|
4 mm²
|
0,5 mm²
|
4 mm²
|
0,5 mm²
|
2,5 mm²
|
12
|
20
|
10 mm
|
300 V
|
10 A
|
300 V
|
10 A
|
EN 60947-7-1:2009, EN 60947-7-3:2009
|
DE
|
19 g
|
100
|
| ||
ZTRK 2,5/3A/ZS BU
Art:
3621.5
Copied
|
2,5 mm²
|
Blue
|
|
|
18 A
|
5 x 20 mm
|
TS 35
|
6 kV
|
CSA, CSA US, KEMA KUR
|
with fuse plug
|
80,2 mm
|
5,1 mm
|
78,7 mm
|
3
|
1
|
A3
|
1
|
2
|
0,5 mm²
|
4 mm²
|
0,5 mm²
|
4 mm²
|
0,5 mm²
|
2,5 mm²
|
12
|
20
|
10 mm
|
300 V
|
10 A
|
300 V
|
10 A
|
EN 60947-7-1:2009, EN 60947-7-3:2009
|
DE
|
19 g
|
100
|
| ||
ZTRK 2,5/3A/ZS 36 BG
Art:
3622.2
Copied
|
2,5 mm²
|
Beige
|
|
|
18 A
|
5 x 20 mm
|
TS 35
|
6 kV
|
CSA, CSA US, KEMA KUR
|
with fuse plug + status display 10-36V
|
80,2 mm
|
5,1 mm
|
78,7 mm
|
3
|
1
|
A3
|
1
|
2
|
0,5 mm²
|
4 mm²
|
0,5 mm²
|
4 mm²
|
0,5 mm²
|
2,5 mm²
|
12
|
20
|
10 mm
|
300 V
|
10 A
|
300 V
|
10 A
|
EN 60947-7-1:2009, EN 60947-7-3:2009
|
DE
|
19 g
|
100
|
| ||
ZTRK 2,5/3A/ZS 70 BG
Art:
3623.2
Copied
|
2,5 mm²
|
Beige
|
|
|
18 A
|
5 x 20 mm
|
TS 35
|
6 kV
|
CSA, CSA US, KEMA KUR
|
with fuse plug + status display 35-70V
|
80,2 mm
|
5,1 mm
|
78,7 mm
|
3
|
1
|
A3
|
1
|
2
|
0,5 mm²
|
4 mm²
|
0,5 mm²
|
4 mm²
|
0,5 mm²
|
2,5 mm²
|
12
|
20
|
10 mm
|
300 V
|
10 A
|
300 V
|
10 A
|
EN 60947-7-1:2009, EN 60947-7-3:2009
|
DE
|
19 g
|
100
|
| ||
ZTRK 2,5/3A/ZS 150 BG
Art:
3624.2
Copied
|
2,5 mm²
|
Beige
|
|
|
18 A
|
5 x 20 mm
|
TS 35
|
6 kV
|
CSA, CSA US, KEMA KUR
|
with fuse plug + status display 60-150V
|
80,2 mm
|
5,1 mm
|
78,7 mm
|
3
|
1
|
A3
|
1
|
2
|
0,5 mm²
|
4 mm²
|
0,5 mm²
|
4 mm²
|
0,5 mm²
|
2,5 mm²
|
12
|
20
|
10 mm
|
300 V
|
10 A
|
300 V
|
10 A
|
EN 60947-7-1:2009, EN 60947-7-3:2009
|
DE
|
19 g
|
100
|
| ||
ZTRK 2,5/3A/ZS 250 BG
Art:
3625.2
Copied
|
2,5 mm²
|
Beige
|
|
|
18 A
|
5 x 20 mm
|
TS 35
|
6 kV
|
CSA, CSA US, KEMA KUR
|
with fuse plug + status display 140-250V
|
80,2 mm
|
5,1 mm
|
78,7 mm
|
3
|
1
|
A3
|
1
|
2
|
0,5 mm²
|
4 mm²
|
0,5 mm²
|
4 mm²
|
0,5 mm²
|
2,5 mm²
|
12
|
20
|
10 mm
|
300 V
|
10 A
|
300 V
|
10 A
|
EN 60947-7-1:2009, EN 60947-7-3:2009
|
DE
|
19 g
|
100
|
| ||
ZTRK 2,5/4A/ZS BG
Art:
3626.2
Copied
|
2,5 mm²
|
Beige
|
|
|
18 A
|
5 x 20 mm
|
TS 35
|
6 kV
|
CSA, CSA US, KEMA KUR
|
with fuse plug
|
92,4 mm
|
5,1 mm
|
78,7 mm
|
4
|
1
|
A3
|
1
|
2
|
0,5 mm²
|
4 mm²
|
0,5 mm²
|
4 mm²
|
0,5 mm²
|
2,5 mm²
|
12
|
20
|
10 mm
|
300 V
|
10 A
|
300 V
|
10 A
|
EN 60947-7-1:2009, EN 60947-7-3:2009
|
DE
|
21 g
|
100
|
| ||
ZTRK 2,5/4A/ZS BU
Art:
3626.5
Copied
|
2,5 mm²
|
Blue
|
|
|
18 A
|
5 x 20 mm
|
TS 35
|
6 kV
|
CSA, CSA US, KEMA KUR
|
with fuse plug
|
92,4 mm
|
5,1 mm
|
78,7 mm
|
4
|
1
|
A3
|
1
|
2
|
0,5 mm²
|
4 mm²
|
0,5 mm²
|
4 mm²
|
0,5 mm²
|
2,5 mm²
|
12
|
20
|
10 mm
|
300 V
|
10 A
|
300 V
|
10 A
|
EN 60947-7-1:2009, EN 60947-7-3:2009
|
DE
|
21 g
|
100
|
| ||
ZTRK 2,5/4A/ZS 36 BG
Art:
3627.2
Copied
|
2,5 mm²
|
Beige
|
|
|
18 A
|
5 x 20 mm
|
TS 35
|
6 kV
|
CSA, CSA US, KEMA KUR
|
with fuse plug + status display 10-36V
|
92,4 mm
|
5,1 mm
|
78,7 mm
|
4
|
1
|
A3
|
1
|
2
|
0,5 mm²
|
4 mm²
|
0,5 mm²
|
4 mm²
|
0,5 mm²
|
2,5 mm²
|
12
|
20
|
10 mm
|
300 V
|
10 A
|
300 V
|
10 A
|
EN 60947-7-1:2009, EN 60947-7-3:2009
|
DE
|
21 g
|
100
|
| ||
ZTRK 2,5/4A/ZS 70 BG
Art:
3628.2
Copied
|
2,5 mm²
|
Beige
|
|
|
18 A
|
5 x 20 mm
|
TS 35
|
6 kV
|
CSA, CSA US, KEMA KUR
|
with fuse plug + status display 35-70V
|
92,4 mm
|
5,1 mm
|
78,7 mm
|
4
|
1
|
A3
|
1
|
2
|
0,5 mm²
|
4 mm²
|
0,5 mm²
|
4 mm²
|
0,5 mm²
|
2,5 mm²
|
12
|
20
|
10 mm
|
300 V
|
10 A
|
300 V
|
10 A
|
EN 60947-7-1:2009, EN 60947-7-3:2009
|
DE
|
21 g
|
100
|
| ||
ZTRK 2,5/4A/ZS 150 BG
Art:
3629.2
Copied
|
2,5 mm²
|
Beige
|
|
|
18 A
|
5 x 20 mm
|
TS 35
|
6 kV
|
CSA, CSA US, KEMA KUR
|
with fuse plug + status display 60-150V
|
92,4 mm
|
5,1 mm
|
78,7 mm
|
4
|
1
|
A3
|
1
|
2
|
0,5 mm²
|
4 mm²
|
0,5 mm²
|
4 mm²
|
0,5 mm²
|
2,5 mm²
|
12
|
20
|
10 mm
|
300 V
|
10 A
|
300 V
|
10 A
|
EN 60947-7-1:2009, EN 60947-7-3:2009
|
DE
|
21 g
|
100
|
| ||
ZTRK 2,5/4A/ZS 250 BG
Art:
3630.2
Copied
|
2,5 mm²
|
Beige
|
|
|
18 A
|
5 x 20 mm
|
TS 35
|
6 kV
|
CSA, CSA US, KEMA KUR
|
with fuse plug + status display 140-250V
|
92,4 mm
|
5,1 mm
|
78,7 mm
|
4
|
1
|
A3
|
1
|
2
|
0,5 mm²
|
4 mm²
|
0,5 mm²
|
4 mm²
|
0,5 mm²
|
2,5 mm²
|
12
|
20
|
10 mm
|
300 V
|
10 A
|
300 V
|
10 A
|
EN 60947-7-1:2009, EN 60947-7-3:2009
|
DE
|
21 g
|
100
|
| ||
ZS/H0/ZTR
Art:
3635.2
Copied
|
|
Yellow
|
|
|
|
5 x 20 mm
|
|
4 kV
|
CSA, CSA US
|
without status display
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
300 V
|
10 A
|
300 V
|
10 A
|
|
DE
|
6,55 g
|
20
|
|
Select a variant in the list
If you need any help, you can contact us in one of the following ways: