Important notice - We will be performing system maintenance from 4pm Friday 19th April. Whilst we are performing this maintenance there will be no pricing available or ability to place orders. This will last for 2-3 days. Please contact customer support for any enquiries 0116 284 9900. We apologise for any inconvenience caused.
PULS
The power supply units supply the AS-Interface system with power via the yellow AS-Interface cable. Communications between the various slaves are modulated and are embedded in the power supply's output voltage. A special power supply is therefore required that does not filter out the data information.
The IR addressing mode is selectable via a switch on the front. When the IR mode is activated, communications are disconnected on the yellow AS-Interface cable. The slaves in the loop can then be simply readdressed without physical disconnection from the interface cable. Once programming is completed, the power supply unit is connected for communications mode and data communications is restarted.
Earth fault monitoring: SLA4 has earth fault monitoring between the AS-Interface cable and earth. In the event of short circuiting between +30.5 V dc or minus to earth, the power supply unit will indicate an alarm via a relay contact and a flashing LED. The power supply unit will continue to supply power to the connected slaves when a fault is detected. The fault is acknowledged by pressing a button on the front of the unit. If a separate earthis not installed between the machine and SLA4.100, we recommend earthing the Shield input via the primary side's earth. Do not leave the Shield connection open.
Fuse mode: SLA8 has a fuse mode. In the event of a short circuit, the power supply unit will produce a high short-circuit current for a few seconds (max. 5 s). The unit will then trip its electronic fuse. A tripped fuse is indicated by a flashing LED. To reset the unit, press the reset button at the front. This function entails that unintentional restarts are prevented and the connected units are protected from damage. For more technical information, see the general information section at the beginning of the power supply chapter.
Input data |
|
---|---|
Input voltage ac | 100-120, 220-240 V |
Input voltage ac min | 85 V AC |
Input voltage ac max | 264 V AC |
Inrush current at 120 V ac typical | 20 A |
Inrush current at 230 V ac typical | 38 A |
Input voltage range | Auto-select |
Power factor at 120 V ac, full load. Typical | 0,5 |
Power factor at 230 V ac, full load. Typical | 0,5 |
Output data |
|
Output voltage | 30,55 V DC |
Output voltage min | 30,55 V DC |
Output voltage max | 30,55 V DC |
Output current | 2,8 A |
Efficiency / Lifetime / MTBF |
|
Efficiency at 230 V ac, full load, typical | 90,5 % |
MTBF (IEC 61709) 230 V ac, max load, 40 ° C | 1942000 h |
Dimensions |
|
Width | 49 mm |
Height | 124 mm |
Depth | 102 mm |
*Invisible Heading* |
|
---|---|
Weight | 0,5 kg |
Other |
|
Approvals | CB, CE, CSA, NEC Class 2, UL |
Hold time at 120 V ac, typical full load | 26 ms |
Hold time at 230 V ac, typical full load | 26 ms |
IP class | IP20 |
Material protection | Aluminium |
Supply frequency | 50-60 ±6 % |
Ripple max | 50 mV pp |
Series | Silverline |
Power consumption 120 V ac | 2 A |
Power consumption 230 V ac | 0,9 A |
Power drop from +60 °C to + 70 °C | 2 W/°C |
Temperature min without derating | -10 °C |
Temperature max without derating | 60 °C |
Type Power Supply | AS-Interface |
The power supply units supply the AS-Interface system with power via the yellow AS-Interface cable. Communications between the various slaves are modulated and are embedded in the power supply's output voltage. A special power supply is therefore required that does not filter out the data information.
The IR addressing mode is selectable via a switch on the front. When the IR mode is activated, communications are disconnected on the yellow AS-Interface cable. The slaves in the loop can then be simply readdressed without physical disconnection from the interface cable. Once programming is completed, the power supply unit is connected for communications mode and data communications is restarted.
Earth fault monitoring: SLA4 has earth fault monitoring between the AS-Interface cable and earth. In the event of short circuiting between +30.5 V dc or minus to earth, the power supply unit will indicate an alarm via a relay contact and a flashing LED. The power supply unit will continue to supply power to the connected slaves when a fault is detected. The fault is acknowledged by pressing a button on the front of the unit. If a separate earthis not installed between the machine and SLA4.100, we recommend earthing the Shield input via the primary side's earth. Do not leave the Shield connection open.
Fuse mode: SLA8 has a fuse mode. In the event of a short circuit, the power supply unit will produce a high short-circuit current for a few seconds (max. 5 s). The unit will then trip its electronic fuse. A tripped fuse is indicated by a flashing LED. To reset the unit, press the reset button at the front. This function entails that unintentional restarts are prevented and the connected units are protected from damage. For more technical information, see the general information section at the beginning of the power supply chapter.
Renowned for high-quality cable cutting and crimping tools, Klauke serves electrical contractors, cable jointers, and linemen across a spectrum of sectors
At OEM Automatic, we can supply a series of components for your one project. All under one roof. This case study discusses how we supplied several components for our customer's new electro-pneumatic control box.
To promote constant and reliable performance, as well as a longer life of parts in the vehicle, it is important to consider the right cable protector.
We have now added switch disconnectors to our range! Switch disconnectors contribute to the overall functionality and safety of electrical systems.
LOCC-Box from Lutze is an intelligent current monitoring device that provides reliable protection of DC circuits in a slimline 8.1mm housing.
OEM Automatic has integrated push-in technology into it's product offering for many years now. In this blog post, we'll explore the various benefits of push-in technology and some of the products we offer that make use of this innovation, such as push-in terminals, push-in sockets, and even push-in heaters.
|
|
|
|
|
||
---|---|---|---|---|---|---|
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
Parts | Inrush current at 120 V ac typical | Inrush current at 230 V ac typical | Power factor at 120 V ac, full load. Typical | Power factor at 230 V ac, full load. Typical | Output voltage min | Output voltage max | Output current | Efficiency at 230 V ac, full load, typical | MTBF (IEC 61709) 230 V ac, max load, 40 ° C | Width | Weight | Approvals | Hold time at 120 V ac, typical full load | Hold time at 230 V ac, typical full load | Power consumption 120 V ac | Power consumption 230 V ac | Power drop from +60 °C to + 70 °C | Price | ||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ASI PSU 100-120/220-240V ac I/P 30.5V dc 2.8A O/P
Art:
SLA3.100
Copied
|
20 A
|
38 A
|
0,5
|
0,5
|
30,55 V DC
|
30,55 V DC
|
2,8 A
|
90,5 %
|
1942000 h
|
49 mm
|
0,5 kg
|
CB, CE, CSA, NEC Class 2, UL
|
26 ms
|
26 ms
|
2 A
|
0,9 A
|
2 W/°C
|
| ||
ASI PSU 100-120/220-240V ac I/P 30.5V dc 4A O/P
Art:
SLA4.100
Copied
|
45 A
|
50 A
|
0,53
|
0,53
|
30,5 V DC
|
30,5 V DC
|
4 A
|
88 %
|
1222000 h
|
65 mm
|
0,62 kg
|
CB, CE, CSA, UL
|
30 ms
|
30 ms
|
2,7 A
|
1,3 A
|
3 W/°C
|
| ||
ASI PSU 100-120/220-240V ac I/P 30.5V dc 8A O/P
Art:
SLA8.100
Copied
|
14 A
|
25 A
|
0,48
|
0,48
|
30,5 V DC
|
30,5 V DC
|
8 A
|
92 %
|
869000 h
|
91 mm
|
0,89 kg
|
CB, CE, CSA, UL
|
10 ms
|
10 ms
|
6 A
|
2,8 A
|
6 W/°C
|
|