PULS
Dimension X series is a series of semi-regulated power supplies. A so-called semi-controlled unit means that the output voltage is regulated within the specified input voltage range. Outside this range decreases / increases the output voltage compared to the input voltage.
The unit has a bonus effect of 25% (25 A) to cope with high starting currents, as well as a very high short-circuit current enables safe trips for eg MCB. The unit leaves up to 90 A at 100 ms. Lasts short circuit longer than 100 ms, the unit shuts off automatically. See chart below for details. Recovery occurs in the front, or by disconnecting the primary voltage.
A yellow LED indicates the status and warns of the following errors; phase failure, over-temperature and high load current.
The unit has a low weight (1.4 kg), no inrush current and active transient filter that protects the secondary side from transients on the primary side.
Typical applications include motors, solenoids or other "power hungry" loads that do not have requirements for accurate voltage regulation. X series are a great alternative to traditional transformers. With lower energy costs and easier installation, along with an attractive price concept means a low total cost.
We recommend free space of 40 mm above and 20 mm under the power supply, and 5 mm at the sides. (if neighbouring products are counted as a heat source spacing of 15 mm is recommended).
Input voltage range/regulation |
Output characteristics |
Input data |
|
---|---|
Input voltage ac | 400 V |
Input voltage ac min | 360 V AC |
Input voltage ac max | 440 V AC |
Inrush current at 400 V ac typical | 4 A |
Power factor at 400 V ac, full load. Typical | 0,93 |
Number of phases | 3 |
Output data |
|
Output voltage | 48 V DC |
Output voltage min | 48 V DC |
Output voltage max | 48 V DC |
Output current | 20 A |
Power | 960 W |
Efficiency / Lifetime / MTBF |
|
Efficiency at 400 V ac, full load, typical | 96 % |
Lifetime at 400 V ac, full load and +40 ° C | 77000 h |
MTBF (IEC 61709) 400 V ac, max loan, +40 °C | 541000 h |
Dimensions |
|
Width | 96 mm |
Height | 124 mm |
Depth | 159 mm |
Weight | 1,4 kg |
*Invisible Heading* |
|
---|---|
Other |
|
Approvals | CB, CE, CSA, UL |
Hold time at 400 V ac, typical full load | 3 ms |
IP class | IP20 |
Material protection | Aluminium |
Supply frequency | 50-60 ±6 % |
Ripple max | 300 mV pp |
Series | Dimension X |
Power consumption at 400 V ac | 1,65 A |
Power drop from +60 °C to + 70 °C | 24 W/°C |
Temperature min without derating | -25 °C |
Temperature max without derating | 60 °C |
Type Power Supply | AC-DC |
Active Transient | Yes |
Dimension X series is a series of semi-regulated power supplies. A so-called semi-controlled unit means that the output voltage is regulated within the specified input voltage range. Outside this range decreases / increases the output voltage compared to the input voltage.
The unit has a bonus effect of 25% (25 A) to cope with high starting currents, as well as a very high short-circuit current enables safe trips for eg MCB. The unit leaves up to 90 A at 100 ms. Lasts short circuit longer than 100 ms, the unit shuts off automatically. See chart below for details. Recovery occurs in the front, or by disconnecting the primary voltage.
A yellow LED indicates the status and warns of the following errors; phase failure, over-temperature and high load current.
The unit has a low weight (1.4 kg), no inrush current and active transient filter that protects the secondary side from transients on the primary side.
Typical applications include motors, solenoids or other "power hungry" loads that do not have requirements for accurate voltage regulation. X series are a great alternative to traditional transformers. With lower energy costs and easier installation, along with an attractive price concept means a low total cost.
We recommend free space of 40 mm above and 20 mm under the power supply, and 5 mm at the sides. (if neighbouring products are counted as a heat source spacing of 15 mm is recommended).
Input voltage range/regulation |
Output characteristics |
At OEM Automatic, we can supply a series of components for your one project. All under one roof. This case study discusses how we supplied several components for our customer's new electro-pneumatic control box.
To promote constant and reliable performance, as well as a longer life of parts in the vehicle, it is important to consider the right cable protector.
We have now added switch disconnectors to our range! Switch disconnectors contribute to the overall functionality and safety of electrical systems.
LOCC-Box from Lutze is an intelligent current monitoring device that provides reliable protection of DC circuits in a slimline 8.1mm housing.
OEM Automatic has integrated push-in technology into it's product offering for many years now. In this blog post, we'll explore the various benefits of push-in technology and some of the products we offer that make use of this innovation, such as push-in terminals, push-in sockets, and even push-in heaters.
We present Kublers ultimate package: Encoders and Process Displays, which can be used together to create efficient processes.
|
|
|
|
|
||
---|---|---|---|---|---|---|
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
Parts | Input voltage ac | Input voltage ac min | Input voltage ac max | Power consumption at 400 V ac | Price | ||
---|---|---|---|---|---|---|---|
PSU 3PH 400V ac I/P 48V dc 20A 960W O/P
Art:
XT40.481
Copied
|
400 V
|
360 V AC
|
440 V AC
|
1,65 A
|
| ||
PSU 3PH 480V ac I/P 48V dc 20A 960W O/P
Art:
XT40.482
Copied
|
480 V
|
432 V AC
|
528 V AC
|
1,4 A
|
|
Select a variant in the list