PULS
Puls Dimension C is a series of very high quality, reliability and performance.
CT10 has built primary fuses that make it possible to connect the unit without the need for intermediate fuses up to 32 A (UL) which saves space and money.
The efficiency is high over a wide load range, which results in reduced power consumption and longer life regardless of load current. An average efficiency of 50% to 100% load is 92% with a peak value of 92.8%.
The short circuit current is 3 x rated current for 20 ms, which helps secondary fuses. Power boost of 20% enables higher current extraction without voltage drops. This is especially useful during start-ups and to bridge the current peaks in the application. Power can be used continually up to +45°C and short periods from +45°C to +60°C.
Active transient ensure operation also in very interference rich electrical environment in addition, CT10 active inrush current protection, which means a very low starting current, even if the unit has been in operation for a longer time. Especially useful for redundant/parallel-connected systems.
Power supply connected with 3 stages but can operate on only two phases, taking into account the loading and ambient temperature.
We recommend free space of 40 mm above and 20 mm below the unit, and 5 mm on the sides.
Power reserve |
Input data |
|
---|---|
Input voltage ac | 380-480 V |
Input voltage ac min | 323 V AC |
Input voltage ac max | 576 V AC |
Input voltage dc min | 450 V DC |
Input voltage dc max | 780 V DC |
Inrush current at 400 V ac typical | 4 A |
Input voltage range | Wide-range |
Power factor at 400 V ac, full load. Typical | 0,53 |
Number of phases | 3 |
Output data |
|
Output voltage | 48 V DC |
Output voltage min | 48 V DC |
Output voltage max | 56 V DC |
Output current | 5 A |
Power | 240 W |
Efficiency / Lifetime / MTBF |
|
Efficiency at 400 V ac, typical | 92 % |
Efficiency at 400 V ac, full load, typical | 92,8 % |
Lifetime at 400 V ac, full load and +40 ° C | 122000 h |
MTBF (IEC 61709) 400 V ac, max loan, +40 °C | 1051000 h |
Width | 62 mm |
Dimensions |
|
---|---|
Height | 124 mm |
Depth | 117 mm |
Weight | 0,75 kg |
Other |
|
Approvals | ABS, CB, CE, CSA US, cRUus, cULus, GL |
Hold time at 400 V ac, typical full load | 34 ms |
IP class | IP20 |
Clamp type | Screw |
Material protection | Aluminium |
Supply frequency | 50-60 ±6 % |
Ripple max | 50 mV pp |
Series | Dimension C |
Power consumption at 400 V ac | 0,7 A |
Power drop from +60 °C to + 70 °C | 6 W/°C |
Temperature min without derating | -25 °C |
Temperature max without derating | 60 °C |
Type Power Supply | AC-DC |
Active Transient | Yes |
Puls Dimension C is a series of very high quality, reliability and performance.
CT10 has built primary fuses that make it possible to connect the unit without the need for intermediate fuses up to 32 A (UL) which saves space and money.
The efficiency is high over a wide load range, which results in reduced power consumption and longer life regardless of load current. An average efficiency of 50% to 100% load is 92% with a peak value of 92.8%.
The short circuit current is 3 x rated current for 20 ms, which helps secondary fuses. Power boost of 20% enables higher current extraction without voltage drops. This is especially useful during start-ups and to bridge the current peaks in the application. Power can be used continually up to +45°C and short periods from +45°C to +60°C.
Active transient ensure operation also in very interference rich electrical environment in addition, CT10 active inrush current protection, which means a very low starting current, even if the unit has been in operation for a longer time. Especially useful for redundant/parallel-connected systems.
Power supply connected with 3 stages but can operate on only two phases, taking into account the loading and ambient temperature.
We recommend free space of 40 mm above and 20 mm below the unit, and 5 mm on the sides.
Power reserve |
At OEM Automatic, we can supply a series of components for your one project. All under one roof. This case study discusses how we supplied several components for our customer's new electro-pneumatic control box.
To promote constant and reliable performance, as well as a longer life of parts in the vehicle, it is important to consider the right cable protector.
We have now added switch disconnectors to our range! Switch disconnectors contribute to the overall functionality and safety of electrical systems.
LOCC-Box from Lutze is an intelligent current monitoring device that provides reliable protection of DC circuits in a slimline 8.1mm housing.
OEM Automatic has integrated push-in technology into it's product offering for many years now. In this blog post, we'll explore the various benefits of push-in technology and some of the products we offer that make use of this innovation, such as push-in terminals, push-in sockets, and even push-in heaters.
We present Kublers ultimate package: Encoders and Process Displays, which can be used together to create efficient processes.
|
|
|
|
|
||
---|---|---|---|---|---|---|
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
Parts | Price | ||
---|---|---|---|
PSU 3PH 380-480V ac I/P 48V dc 5A 240W O/P
Art:
CT10.481
Copied
|
|
Select a variant in the list
If you need any help, you can contact us in one of the following ways: