Important notice - We will be performing system maintenance from 4pm Friday 19th April. Whilst we are performing this maintenance there will be no pricing available or ability to place orders. This will last for 2-3 days. Please contact customer support for any enquiries 0116 284 9900. We apologise for any inconvenience caused.
PULS
Puls Dimension C-series stands for cost optimization without compromising quality, reliability or performance. CPS20.241 high efficiency over a wide load range, which results in reduced power consumption and longer life regardless of load current. An average efficiency is 93.3% with a peak of 94%. In addition, power losses very low at idle, only 2.6 W at 230 Vac. Power boost of 20% enables higher current extraction without voltage drops. This is especially useful during start-ups and to bridge the current peaks in the application. The power reserve can be used continuously up to +45°C and short periods from +45 to +60°C.
Short-circuit currents. CPS20 can leave short-circuit currents which is 4 times the nominal current for 15 ms, which helps secondary fuses and achieve selectivity.
Hiccup Plus.
With new pulse short circuit protection you get optimum protection. The unit leaves a very high short circuit that solves fuses and provides sufficient starting current for example DC motors. If the output voltage drops below 13 V dc will be 2x the rated current is left for 2 seconds, then close the unit by the end to make a new restart attempts after about 18 seconds. This feature ensures a high short-circuit / overload current while avoiding a constant high current that can lead to heat and component damage.
Technical advantages. CPS20 has active power factor correction (PFC) and actively ströminrusningsskydd that effectively reduces start currents which are ideal if several units are connected in the same phase or if the supply is current limited through example. AC UPS. The protection is always active, regardless of the temperature. DC-OK output, wide temperature range, a large number of approvals and transient filter which ensures operation in störrik electrical environment makes the unit suitable for virtually all installations.
Â
Â
Output characteristics | Efficiency |
 | |
Peak current at short circuit | Stripping secondary Fuses |
Type 90 A for 15 ms enables tripping of example MCBs |
Â
Input data |
|
---|---|
Input voltage ac | 100-240 V |
Input voltage ac min | 85 V AC |
Input voltage ac max | 264 V AC |
Inrush current at 120 V ac typical | 9 A |
Inrush current at 230 V ac typical | 7 A |
Input voltage range | Wide-range |
Power factor at 120 V ac, full load. Typical | 0,99 |
Power factor at 230 V ac, full load. Typical | 0,95 |
Number of phases | 1 |
Output data |
|
Output voltage | 24 V DC |
Output voltage min | 24 V DC |
Output voltage max | 28 V DC |
Output current | 20 A |
Power | 480 W |
Efficiency / Lifetime / MTBF |
|
Efficiency at 120 V ac, full load, typical | 92,7 % |
Efficiency at 230 V ac, typical | 93,3 % |
Efficiency at 230 V ac, full load, typical | 94 % |
Lifetime at 120 V ac, full load and +40 ° C | 70000 h |
Lifetime at 230 V ac, full load and +40 ° C | 88000 h |
MTBF (IEC 61709) 230 V ac, max load, 40 ° C | 537000 h |
Dimensions |
|
Width | 65 mm |
*Invisible Heading* |
|
---|---|
Height | 124 mm |
Depth | 127 mm |
Weight | 1 kg |
Other |
|
Approvals | ABS, CB, CE, CSA, EX, GL, IECEx, UL |
Hold time at 120 V ac, typical full load | 26 ms |
Hold time at 230 V ac, typical full load | 26 ms |
IP class | IP20 |
Clamp type | Screw on |
Material protection | Aluminium |
Supply frequency | 50-60 ±6 % |
Ripple max | 50 mV pp |
Series | Dimension C |
Power consumption 120 V ac | 4,36 A |
Power consumption 230 V ac | 2,33 A |
Power drop from +60 °C to + 70 °C | 12 W/°C |
Temperature min without derating | -25 °C |
Temperature max without derating | 60 °C |
Type Power Supply | AC-DC |
DC relay output | Yes |
Active Transient | Yes |
Puls Dimension C-series stands for cost optimization without compromising quality, reliability or performance. CPS20.241 high efficiency over a wide load range, which results in reduced power consumption and longer life regardless of load current. An average efficiency is 93.3% with a peak of 94%. In addition, power losses very low at idle, only 2.6 W at 230 Vac. Power boost of 20% enables higher current extraction without voltage drops. This is especially useful during start-ups and to bridge the current peaks in the application. The power reserve can be used continuously up to +45°C and short periods from +45 to +60°C.
Short-circuit currents. CPS20 can leave short-circuit currents which is 4 times the nominal current for 15 ms, which helps secondary fuses and achieve selectivity.
Hiccup Plus.
With new pulse short circuit protection you get optimum protection. The unit leaves a very high short circuit that solves fuses and provides sufficient starting current for example DC motors. If the output voltage drops below 13 V dc will be 2x the rated current is left for 2 seconds, then close the unit by the end to make a new restart attempts after about 18 seconds. This feature ensures a high short-circuit / overload current while avoiding a constant high current that can lead to heat and component damage.
Technical advantages. CPS20 has active power factor correction (PFC) and actively ströminrusningsskydd that effectively reduces start currents which are ideal if several units are connected in the same phase or if the supply is current limited through example. AC UPS. The protection is always active, regardless of the temperature. DC-OK output, wide temperature range, a large number of approvals and transient filter which ensures operation in störrik electrical environment makes the unit suitable for virtually all installations.
Â
Â
Output characteristics | Efficiency |
 | |
Peak current at short circuit | Stripping secondary Fuses |
Type 90 A for 15 ms enables tripping of example MCBs |
Â
Renowned for high-quality cable cutting and crimping tools, Klauke serves electrical contractors, cable jointers, and linemen across a spectrum of sectors
At OEM Automatic, we can supply a series of components for your one project. All under one roof. This case study discusses how we supplied several components for our customer's new electro-pneumatic control box.Â
To promote constant and reliable performance, as well as a longer life of parts in the vehicle, it is important to consider the right cable protector.
We have now added switch disconnectors to our range! Switch disconnectors contribute to the overall functionality and safety of electrical systems.
LOCC-Box from Lutze is an intelligent current monitoring device that provides reliable protection of DC circuits in a slimline 8.1mm housing.
OEM Automatic has integrated push-in technology into it's product offering for many years now. In this blog post, we'll explore the various benefits of push-in technology and some of the products we offer that make use of this innovation, such as push-in terminals, push-in sockets, and even push-in heaters.
|
|
|
|
|
||
---|---|---|---|---|---|---|
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
Parts | Input voltage ac | Input voltage ac min | Input voltage ac max | Input voltage dc | Input voltage dc min | Input voltage dc max | Inrush current | Inrush current at 120 V ac typical | Inrush current at 230 V ac typical | Input voltage range | Max entrance tripple | Power factor at 120 V ac, full load. Typical | Power factor at 230 V ac, full load. Typical | Number of phases | Efficiency | Efficiency at 120 V ac, full load, typical | Efficiency at 230 V ac, typical | Efficiency at 230 V ac, full load, typical | Life span | Lifetime at 120 V ac, full load and +40 ° C | Lifetime at 230 V ac, full load and +40 ° C | MTBF (IEC 61709) | MTBF (IEC 61709) 230 V ac, max load, 40 ° C | Weight | Approvals | Keep time | Hold time at 120 V ac, typical full load | Hold time at 230 V ac, typical full load | Supply frequency | Ripple max | Power consumption 120 V ac | Power consumption 230 V ac | Startup delay | Conformal coated | Price | ||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
PSU 100-240V ac I/P 24V dc 20A 480W O/P
Art:
CPS20.241
Copied
|
100-240 V
|
85 V AC
|
264 V AC
|
|
|
|
|
9 A
|
7 A
|
Wide-range
|
|
0,99
|
0,95
|
1
|
|
92,7 %
|
93,3 %
|
94 %
|
|
70000 h
|
88000 h
|
|
537000 h
|
1 kg
|
ABS, CB, CE, CSA, EX, GL, IECEx, UL
|
|
26 ms
|
26 ms
|
50-60 ±6 %
|
50 mV pp
|
4,36 A
|
2,33 A
|
|
|
| ||
PSU 100-240V ac I/P 24V dc 20A 480W O/P Conf. Coated
Art:
CPS20.241-C1
Copied
|
100-240 V
|
85 V AC
|
264 V AC
|
|
|
|
|
9 A
|
7 A
|
Wide-range
|
|
0,99
|
0,95
|
1
|
|
92,7 %
|
93,3 %
|
94 %
|
|
70000 h
|
88000 h
|
|
537000 h
|
1 kg
|
ABS, CB, CE, CSA, EAC, EN 50155, EX, GL, IECEx, UL
|
|
26 ms
|
26 ms
|
50-60 ±6 %
|
50 mV pp
|
4,36 A
|
2,33 A
|
|
Yes
|
| ||
PSU 110-300V dc I/P 24V dc 20A 480W O/P
Art:
CPS20.241-D1
Copied
|
|
|
|
110-300 V
|
88 V DC
|
360 V DC
|
Typ. 6/4 A @ 110/300 V DC
|
|
|
|
50 V pp
|
|
|
|
93,1 %
|
|
|
|
110 V DC: 81000 h @ 24 V DC, 20 A, 40 °C
|
|
|
110 V DC: 468000 h @ 24 V DC, 20 A, 40 °C
|
|
0,94 kg
|
CB, CE, CSA, EX, IECEx, UL
|
Typ. 26/26 ms @ 110/300 V DC
|
|
|
|
70 mV pp
|
|
|
1100 ms
|
|
|