• black icon of a bullhorn 30 years industry experience
  • black icon of three cubes Over 8,000 products in stock
  • Black icon of a clock Order by 16:00 and receive the next working day
LUMEL
LUMEL

Digital Display Panel, DNL

  • RS485 MODBUS or analogue signal input
  • Displays data from upto 10 devices
  • MODBUS master or slave

Product description

 

Technical

External Features

 

Readout field

1 row x 4 digits
or 2 rows x 4 digits

DNL2 – digit height 230 mm
DNL3 – digit height 305 mm

 

Overall dimensions

acc. to the table 1 and fig. 1

 

 

Weight DNL2

one row : 5,4 kg

two rows: 10,8 kg

 

Weight DNL3

one row: 7,6 kg

two rows: 15,2 kg

 

Protec! on grade

for housing: IP40

for terminals: IP10

 

 

 

 

 

Digital Interface

 

Interface type

Mode

Baud rate

 

RS-485 Modbus RTU Slave

8N1, 8N2, 8E1, 8O1

2.4, 4.8, 9.6, 14.4, 19.2, 28.8,
38.4, 57.6, 76.8, 115.2. kbit/s

 

RS485 Modbus RTU Master

8N1, 8N2, 8E1, 8O1

2.4, 4.8, 9.6, 14.4, 19.2, 28.8,
38.4, 57.6, 76.8, 115.2 kbit/s

 

 

 

 

 

Inputs

 

Input type

Range

Error

 

RS485 Modbus RTU Master

 

 

 

current

4…20 mA d.c.

- basic error: 0.1%
- additional error from temperature
changes: 0.05 %/10 °C

 

 

 

 

 

Outputs

 

Output type

Properties

 

supplying output for transducers

15V d.c. / 50mA

 

 

 

 

Rated Operating Conditions

 

Supply voltage

100...240 V a.c.

50..60 Hz

 

Power consumption

< 55 VA

 

 

Temperature

ambient: -10...23...50°C

storage: -25...75°C

 

Relative humidity

25 .. 95%

inadmissible condensa! on

 

Operating position

any

 

 

External magnetic field

0...40...400 A/m

 

 

 

 

 

 

Safety and Compatibility Requirements

 

Electromagnetic compatibility

Noise immunity

wg PN-EN 61000-6-2

 

Noise emissions

wg PN-EN 61000-6-4

 

Isolation between circuits

bsic

wg PN-EN 61010-1

 

Pollution level

2

 

Installation category

III

 

Maximum phase-to-earth operating voltage

- for supply and measuring circuits 300V
- for other circuits 50 V

 

Altitude above seal level

<2000 m

 

 

Connection diagram

 

Dimensions

One row version

Two row version

 

 

DNL2
(mm)

DNL3
(mm)

DNL2
(mm)

DNL3
(mm)

 

A

931

1091

931

1091

 

B

905

1065

905

1065

 

C

868

1027

868

1027

 

D

328

414

609

781

 

E

281

367

562

734

 

 

Ordering code


Example of Order:
The code:
DNL-2-Y-01-0-00-00-E-1 means:
display panel with one row with yellow digits, with unit %, standard version, English language, with an extra quality inspection certificate

Code

Unit

 

00

lack

 

01

%

 

02

°C

 

03

szt.

 

04

imp.

 

05

kg

 

06

m/s

 

07

szt./h

 

08

 

09

obr

 

XX

on order

 

 

Parts Price

Part

DNL2R0000000E0
Digital display

Resource

Contact us

If you need any help, you can contact us in one of the following ways:

0116 284 9900

Send an e-mail

Use live chat