Important notice - We will be performing system maintenance from 4pm Friday 19th April. Whilst we are performing this maintenance there will be no pricing available or ability to place orders. This will last for 2-3 days. Please contact customer support for any enquiries 0116 284 9900. We apologise for any inconvenience caused.
STEGO
The heating source in this fan is a high-power resistor element.
Â
Thanks to the fan, good air circulation is obtained, while at the same time high upward dispersal is achieved. The fan is therefore appropriate for installation in enclosures outdoors to maintain an even temperature and thus avoid condensation, but it can also be used to assure that the temperature is kept above the lowest permitted level.
Â
The fan can even be run separately to increase the air circulation during the summer, for example.
General Data |
|
---|---|
Heat output | 100 W |
Nominal voltage | 120 V AC |
Frequency | 50/60 Hz |
Heater body | Aluminium, Plastic |
Material of body | Die cast aluminium |
Mounting | Clip on, DIN rail |
Number of fans | 1 |
Connection type | 3-pole spring terminal for 2.5 mm² cable (1.5 mm² with end sleeve). Fan connected to screw terminal L2 / N2. |
Heat source | Resistor element |
Recommended fuse (slow blow) | 2 A |
Life span | 50 000 h @ +25 °C |
Air capacity | 35 m³/h |
Dimensions |
|
Height | 47 mm |
Width | 80 mm |
Depth | 112 mm |
Weight | 0,6 kg |
Safety & Approvals |
|
---|---|
Protection class | I (earthed) |
IP class | IP20 |
Approvals | CE, cULus, EAC, RoHS, UL |
Flammability class | UL94-V0 |
Overheating protection | In case of fan failure and overheating |
Rated Operating Conditions |
|
Temperature 50 mm above the heater | +75 °C |
Operational temperature | -45°C ... +70°C |
Storage temperature | -45°C ... +70°C |
Operating humidity | < 90% RH |
Humidity storage | <90% RH |
Material plastic housing | Plastic |
Plastic cover | Black, UL94 V-0 |
Voltage max | 120 V ac |
Voltage min | 120 V ac |
The heating source in this fan is a high-power resistor element.
Â
Thanks to the fan, good air circulation is obtained, while at the same time high upward dispersal is achieved. The fan is therefore appropriate for installation in enclosures outdoors to maintain an even temperature and thus avoid condensation, but it can also be used to assure that the temperature is kept above the lowest permitted level.
Â
The fan can even be run separately to increase the air circulation during the summer, for example.
Renowned for high-quality cable cutting and crimping tools, Klauke serves electrical contractors, cable jointers, and linemen across a spectrum of sectors
At OEM Automatic, we can supply a series of components for your one project. All under one roof. This case study discusses how we supplied several components for our customer's new electro-pneumatic control box.Â
To promote constant and reliable performance, as well as a longer life of parts in the vehicle, it is important to consider the right cable protector.
We have now added switch disconnectors to our range! Switch disconnectors contribute to the overall functionality and safety of electrical systems.
LOCC-Box from Lutze is an intelligent current monitoring device that provides reliable protection of DC circuits in a slimline 8.1mm housing.
OEM Automatic has integrated push-in technology into it's product offering for many years now. In this blog post, we'll explore the various benefits of push-in technology and some of the products we offer that make use of this innovation, such as push-in terminals, push-in sockets, and even push-in heaters.
|
|
|
|
|
||
---|---|---|---|---|---|---|
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
||
|
|
|
|
|
Parts | Heat output | Nominal voltage | Number of fans | Connection type | Recommended fuse (slow blow) | Air capacity | Height | Width | Depth | Weight | Approvals | Voltage max | Voltage min | Price | ||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
HVL 031 100W Fan heater, 230V ac
Art:
03102.0-00
Copied
|
100 W
|
230 V AC
|
1
|
3-pole spring terminal for 2.5 mm² cable (1.5 mm² with end sleeve). Fan connected to screw terminal L2 / N2.
|
1 A
|
35 m³/h
|
47 mm
|
80 mm
|
112 mm
|
0,6 kg
|
CE, cULus, EAC, RoHS, UL, VDE
|
230 V ac
|
230 V ac
|
| ||
HVL 031 150W Fan heater, 230V ac
Art:
03103.0-00
Copied
|
150 W
|
230 V AC
|
1
|
3-pole spring terminal for 2.5 mm² cable (1.5 mm² with end sleeve). Fan connected to screw terminal L2 / N2.
|
1,25 A
|
35 m³/h
|
47 mm
|
80 mm
|
112 mm
|
0,6 kg
|
CE, cULus, EAC, RoHS, UL, VDE
|
230 V ac
|
230 V ac
|
| ||
HVL 031 200W Fan heater, 230V ac
Art:
03113.0-00
Copied
|
200 W
|
230 V AC
|
1
|
3-pole spring terminal for 2.5 mm² cable (1.5 mm² with end sleeve). Fan connected to screw terminal L2 / N2.
|
2 A
|
108 m³/h
|
47 mm
|
119 mm
|
151 mm
|
0,9 kg
|
CE, cULus, EAC, RoHS, UL, VDE
|
230 V ac
|
230 V ac
|
| ||
HVL 031 300W Fan heater, 230V ac
Art:
03114.0-00
Copied
|
300 W
|
230 V AC
|
1
|
3-pole spring terminal for 2.5 mm² cable (1.5 mm² with end sleeve). Fan connected to screw terminal L2 / N2.
|
2 A
|
108 m³/h
|
47 mm
|
119 mm
|
151 mm
|
0,9 kg
|
CE, cULus, EAC, RoHS, UL, VDE
|
230 V ac
|
230 V ac
|
| ||
HVL 031 400W Fan heater, 230V ac
Art:
03115.0-00
Copied
|
400 W
|
230 V AC
|
1
|
3-pole spring terminal for 2.5 mm² cable (1.5 mm² with end sleeve). Fan connected to screw terminal L2 / N2.
|
4 A
|
108 m³/h
|
47 mm
|
119 mm
|
151 mm
|
0,9 kg
|
CE, cULus, EAC, RoHS, UL, VDE
|
230 V ac
|
230 V ac
|
| ||
HVL 031 100W Fan heater, 120V ac
Art:
03102.9-00
Copied
|
100 W
|
120 V AC
|
1
|
3-pole spring terminal for 2.5 mm² cable (1.5 mm² with end sleeve). Fan connected to screw terminal L2 / N2.
|
2 A
|
35 m³/h
|
47 mm
|
80 mm
|
112 mm
|
0,6 kg
|
CE, cULus, EAC, RoHS, UL
|
120 V ac
|
120 V ac
|
| ||
HVL 031 150W, Fan heater, 120V ac
Art:
03103.9-00
Copied
|
150 W
|
120 V AC
|
1
|
3-pole spring terminal for 2.5 mm² cable (1.5 mm² with end sleeve). Fan connected to screw terminal L2 / N2.
|
2,5 A
|
35 m³/h
|
47 mm
|
80 mm
|
112 mm
|
0,6 kg
|
CE, cULus, EAC, RoHS, UL
|
120 V ac
|
120 V ac
|
| ||
HVL 031 200W Fan heater, 120V ac
Art:
03113.9-00
Copied
|
200 W
|
120 V AC
|
1
|
3-pole spring terminal for 2.5 mm² cable (1.5 mm² with end sleeve). Fan connected to screw terminal L2 / N2.
|
3 A
|
108 m³/h
|
47 mm
|
119 mm
|
151 mm
|
0,9 kg
|
CE, cULus, EAC, RoHS, UL
|
120 V ac
|
120 V ac
|
| ||
HVL 031 300W Fan heater, 120V ac
Art:
03114.9-00
Copied
|
300 W
|
120 V AC
|
1
|
3-pole spring terminal for 2.5 mm² cable (1.5 mm² with end sleeve). Fan connected to screw terminal L2 / N2.
|
4 A
|
108 m³/h
|
47 mm
|
119 mm
|
151 mm
|
0,9 kg
|
CE, cULus, EAC, RoHS, UL
|
120 V ac
|
120 V ac
|
| ||
HVL 031 400W Fan heater, 120V ac
Art:
03115.9-00
Copied
|
400 W
|
120 V AC
|
1
|
3-pole spring terminal for 2.5 mm² cable (1.5 mm² with end sleeve). Fan connected to screw terminal L2 / N2.
|
6,3 A
|
108 m³/h
|
47 mm
|
119 mm
|
151 mm
|
0,9 kg
|
CE, cULus, EAC, RoHS, UL
|
120 V ac
|
120 V ac
|
| ||
HV 031 100W Heating element without fan, 230V ac
Art:
03100.0-00
Copied
|
100 W
|
230 V AC
|
|
3-pole spring terminal for 2.5 mm² cable (1.5 mm² with end sleeve)
|
1 A
|
|
22 mm
|
80 mm
|
112 mm
|
0,4 kg
|
CE, cULus, EAC, RoHS, UL, VDE
|
230 V ac
|
230 V ac
|
| ||
HV 031 150W Heating element without fan, 230V ac
Art:
03101.0-00
Copied
|
150 W
|
230 V AC
|
|
3-pole spring terminal for 2.5 mm² cable (1.5 mm² with end sleeve)
|
1,25 A
|
|
22 mm
|
80 mm
|
112 mm
|
0,4 kg
|
CE, cULus, EAC, RoHS, UL, VDE
|
230 V ac
|
230 V ac
|
| ||
HV 031 200W Heating element without fan, 230V ac
Art:
03110.0-00
Copied
|
200 W
|
230 V AC
|
|
3-pole spring terminal for 2.5 mm² cable (1.5 mm² with end sleeve)
|
2 A
|
|
22 mm
|
119 mm
|
151 mm
|
0,5 kg
|
CE, cULus, EAC, RoHS, UL, VDE
|
230 V ac
|
230 V ac
|
| ||
HV 031 300W Heating element without fan, 230V ac
Art:
03111.0-00
Copied
|
300 W
|
230 V AC
|
|
3-pole spring terminal for 2.5 mm² cable (1.5 mm² with end sleeve)
|
2 A
|
|
22 mm
|
119 mm
|
151 mm
|
0,5 kg
|
CE, cULus, EAC, RoHS, UL, VDE
|
230 V ac
|
230 V ac
|
| ||
HV 031 400W Heating element without fan, 230V ac
Art:
03112.0-00
Copied
|
400 W
|
230 V AC
|
|
3-pole spring terminal for 2.5 mm² cable (1.5 mm² with end sleeve)
|
4 A
|
|
22 mm
|
119 mm
|
151 mm
|
0,5 kg
|
CE, cULus, EAC, RoHS, UL, VDE
|
230 V ac
|
230 V ac
|
| ||
HV 031 100W Heating element without fan, 120V ac
Art:
03100.9-00
Copied
|
100 W
|
120 V AC
|
|
3-pole spring terminal for 2.5 mm² cable (1.5 mm² with end sleeve)
|
2 A
|
|
22 mm
|
80 mm
|
112 mm
|
0,4 kg
|
CE, cULus, EAC, RoHS, UL, VDE
|
120 V ac
|
120 V ac
|
| ||
HV 031 150W Heating element without fan, 120V ac
Art:
03101.9-00
Copied
|
150 W
|
120 V AC
|
|
3-pole spring terminal for 2.5 mm² cable (1.5 mm² with end sleeve)
|
2,5 A
|
|
22 mm
|
80 mm
|
112 mm
|
0,4 kg
|
CE, cULus, EAC, RoHS, UL, VDE
|
120 V ac
|
120 V ac
|
| ||
HV 031 200W Heating element without fan, 120V ac
Art:
03110.9-00
Copied
|
200 W
|
120 V AC
|
|
3-pole spring terminal for 2.5 mm² cable (1.5 mm² with end sleeve)
|
3 A
|
|
22 mm
|
119 mm
|
151 mm
|
0,5 kg
|
CE, cULus, EAC, RoHS, UL
|
120 V ac
|
120 V ac
|
| ||
HV 031 300W Heating element without fan, 120V ac
Art:
03111.9-00
Copied
|
300 W
|
120 V AC
|
|
3-pole spring terminal for 2.5 mm² cable (1.5 mm² with end sleeve)
|
4 A
|
|
22 mm
|
119 mm
|
151 mm
|
0,5 kg
|
CE, cULus, EAC, RoHS, UL
|
120 V ac
|
120 V ac
|
| ||
HV 031 400W Heating element without fan, 120V ac
Art:
03112.9-00
Copied
|
400 W
|
120 V AC
|
|
3-pole spring terminal for 2.5 mm² cable (1.5 mm² with end sleeve)
|
6,3 A
|
|
22 mm
|
119 mm
|
151 mm
|
0,5 kg
|
CE, cULus, EAC, RoHS, UL
|
120 V ac
|
120 V ac
|
|