A coded magnetic switch made of stainless steel with a small size and high tolerance, which is ideally suited for applications in the food and pharmaceutical industries. The switch has a standard spacing of fixing holes - 22 mm and is resistant to pressure washing. Mounting screws from the bottom makes the switch ideal for demanding food applications.

Read more
  • Stainless steel housing
  • Mounting screws from the bottom
  • For demanding food applications
  • Switching range - 14 mm
  • No dedicated controller

Selected variant

Selected variant

Technical data

Approvals ISO 14119, EN60947-5-1, EN60204-1, ISO 13849-1, EN62061, UL 508
Cable length 10 m
Cable type PVC 6 or 8 core 6mm OD Conductors 0.25mm²
Coding Coded magnetic actuation
Conductor size 0,25 mm²
Contact rating max 24Vdc 0.2A
Contacts 2NC
Housing material Stainless steel 316
Integrated LED indication Yes
IP class IP69K, IP67
Mounting 2 x M4
MTTFd 866 years
Operating temperature -25..105°C
PFHd 8.71 X 10⁻¹¹
PL e acc. ISO13849-1
Recommended mounting gap 5 mm
SIL 3 acc. EN62061
Switching current min 10Vdc 1mA
Switching distance Sao 10mm close, Sar 20mm open
Switching frequency max 1.0Hz maximum

Measurements and connections

Technical illustrations

Product description

A coded magnetic switch made of stainless steel with a small size and high tolerance, which is ideally suited for applications in the food and pharmaceutical industries. The switch has a standard spacing of fixing holes - 22 mm and is resistant to pressure washing. Mounting screws from the bottom makes the switch ideal for demanding food applications.

Accessories

Related

Parts Approvals Cable length Contacts Operating temperature PL SIL Switching distance Price
ISO 14119, EN60947-5-1, EN60204-1, ISO 13849-1, EN62061, UL 508
2 m
2NC
-25..105°C
e acc. ISO13849-1
3 acc. EN62061
ISO 14119, EN60947-5-1, EN60204-1, ISO 13849-1, EN62061, UL 508
5 m
2NC
-25..105°C
e acc. ISO13849-1
3 acc. EN62061
ISO 14119, EN60947-5-1, EN60204-1, ISO 13849-1, EN62061, UL 508
10 m
2NC
-25..105°C
e acc. ISO13849-1
3 acc. EN62061
ISO 14119, EN60947-5-1, EN60204-1, ISO 13849-1, EN62061, UL 508
0,25 m
2NC
-25..105°C
e acc. ISO13849-1
3 acc. EN62061
ISO 13849-1, ISO 14119, EN60204-1, EN62061, EN60947-5-1, CE, cULus, TÜV, UL 508
2 m
2NC 1NO
-25°C - 105°C
up to PLe acc. ISO13849-1
14 mm
ISO 14119, EN60947-5-1, EN60204-1, ISO 13849-1, EN62061, UL 508
5 m
2NC 1NO
-25..105°C
e acc. ISO13849-1
3 acc. EN62061
ISO 14119, EN60947-5-1, EN60204-1, ISO 13849-1, EN62061, UL 508
10 m
2NC 1NO
-25..105°C
e acc. ISO13849-1
3 acc. EN62061
ISO 13849-1, ISO 14119, EN60204-1, EN62061, EN60947-5-1, CE, cULus, TÜV, UL 508
0,25 m
2NC 1NO
-25°C - 105°C
up to PLe acc. ISO13849-1
14 mm
ISO 14119, EN60947-5-1, EN60204-1, ISO 13849-1, EN62061, UL 508
2 m
3NC
-25..105°C
e acc. ISO13849-1
3 acc. EN62061
ISO 14119, EN60947-5-1, EN60204-1, ISO 13849-1, EN62061, UL 508
5 m
3NC
-25..105°C
e acc. ISO13849-1
3 acc. EN62061
ISO 14119, EN60947-5-1, EN60204-1, ISO 13849-1, EN62061, UL 508
10 m
3NC
-25..105°C
e acc. ISO13849-1
3 acc. EN62061
ISO 14119, EN60947-5-1, EN60204-1, ISO 13849-1, EN62061, UL 508
0,25 m
3NC
-25..105°C
e acc. ISO13849-1
3 acc. EN62061