• Over 40 years industry experience
  • Over 8,000 products in stock
  • Order by 16:00 and receive the next working day
CROUZET SWITCHES
CROUZET SWITCHES

V4

  • Load 0.1-10 A 250 V ac
  • Minimum load 1 mA 4 V dc
  • Available with sponge trigger
  • Control arm can be fitted in two different positions

Part numbers

Parts Connection Power min Rated current at 250 V ac Thermal current at 250 V ac Voltage ac max Voltage min
W2 10 A 12,5 A
X1 10 A 12,5 A
W2 0,001 A 5 A 6 A 250 V 4 V

Part

V4-photo

83170802
Microswitch CO W2 0,1A 250VAC

Please login to view price and stock info. Click here to register an account.

Technical data

Connection W2
Contact gap 0,4 mm
Contact type Changeover (SPDT)
Force of the return movement min 0,3 N
Hysteresis max 0,15 mm
IP class IP40
Operating force max 1,5 N
Operating power total max 1,8 N
Overtravel min 0,5 mm
Permissible overvoltage max 10 N
Power min 0,001 A
Rated current at 250 V ac 5 A
Sleep max 9,2 mm
Switching point 8,4 ±0,3 mm
Temperature operational max 125 °C
Temperature operational min -40 °C
Thermal current at 250 V ac 6 A
Voltage ac max 250 V
Voltage min 4 V

Measurements and connections

  • Fixing position: The control arms are supplied unfitted unless specified otherwise.<br />For factory fitting, specify installation position A or B.<br />To calculate the force: divide the breaking force by the coefficient in the table. <br />To calculate movement: multiply the breaking movement by the same coefficient.

    Fixing position: The control arms are supplied unfitted unless specified otherwise.
    For factory fitting, specify installation position A or B.
    To calculate the force: divide the breaking force by the coefficient in the table.
    To calculate movement: multiply the breaking movement by the same coefficient.

  • 1: Number of cycles<br />2: Resistance<br />3: Inductive load<br />4: Mechanical lifetime<br />5: Current

    1: Number of cycles
    2: Resistance
    3: Inductive load
    4: Mechanical lifetime
    5: Current

  • 1: Number of cycles<br />2: Resistance<br />3: Inductive load<br />4: Mechanical lifetime<br />5: Current

    1: Number of cycles
    2: Resistance
    3: Inductive load
    4: Mechanical lifetime
    5: Current

  • 1: Number of cycles<br />2: Resistance<br />3: Inductive load<br />4: Mechanical lifetime<br />5: Current

    1: Number of cycles
    2: Resistance
    3: Inductive load
    4: Mechanical lifetime
    5: Current

  • Changeover<br />Normally closed<br />Normally open

    Changeover
    Normally closed
    Normally open

Contact us

If you need any help, you can contact us in one of the following ways:

0116 284 9900

Send an e-mail

Use live chat