Crouzet - 1 phase over/under current relay HIL, HIH
- Two models: HIL 2 mA-500 mA, HIH 0.1 A-10 A
- Galvanic isolation control/measurement
- Automatic detection of AC or DC

Crouzet - 1 phase over/under voltage relay HUL, HUH
- Two modules, HUL 0.2-60 V, HUH 15-600 V
- Galvanic isolation control/measurement
- Automatic detection of AC or DC

Crouzet - 1 phase over/under voltage relay MUS, MUSF
- Three models with different voltage ranges
- Reconnectible over- or under-voltage
- Automatic detection of AC or DC

Crouzet - 3 phase over/under voltage relay H3US, H3USN
- Phase control of line voltage
- Wide range input voltage
- 35 mm cabinet with DIN rail

Crouzet - 3 phase over/under voltage relay M3US
- Phase control of line voltage
- Wide range input voltage
- 17.5 mm cabinet with DIN rail

Crouzet - 3 phase, phase control HWUA
- Triggers alarm upon incorrect phase sequence, phase interruption, asymmetry and over-/under-voltage
- Adjustable line voltage
- Measures returned voltage to 70 %

Crouzet - 3 phase, phase control MWA
- Triggers alarm upon incorrect phase sequence, phase interruption and asymmetry
- Adjustable line voltage
- Measures returned voltage to 70 %

Crouzet - 3 phase, phase control MWG
- Triggers alarm when phase sequence or phase interruption faults occurs
- Adjustable line voltage
- Measures returned voltage to 70 %

Crouzet - 3 phase, phase control MWS, MWS2
- Triggers alarm upon incorrect phase sequence/phase interruption
- Wide range input voltage from 3x208-480 V AC
- 17.5 mm cabinet with DIN rail

Crouzet - 3 phase, phase control MWU
- Triggers alarm upon incorrect phase sequence, phase interruption and under-voltage
- Adjustable line voltage
- Measures returned voltage to 98 %

Crouzet - 3 phase, phase control MWUA
- Triggers alarm upon incorrect phase sequence, phase interruption, asymmetry and over-/under-voltage
- Adjustable line voltage
- Measures returned voltage to 70 %

Crouzet - Current relay MIC
- Measurement range 2-20 A AC
- Integrated current transformer
- Over-/under-current function

Crouzet - Frequency control relay HHZ
- Control of frequency 50-60 Hz AC network
- Over-/under-frequency with two relay outputs
- 35 mm cabinet with DIN rail

Crouzet - Level control HNM, HNE
- Control of one or two levels
- Filling/emptying function
- HNM resistive sensor

Crouzet - Level control MNS
- With input/output sensor (float)
- 17.5 mm cabinet with DIN rail
- LED indication

Crouzet - Phase and temperature monitoring for motors, HWTM, HWTM2
- Control of 3-phase networks: phase sequence, phase interruption
- Motor temperature monitoring with PTC sensors
- Wide range input voltage

Crouzet - Speed monitoring HSV
- Monitors over-/under-speed
- Adjustable between 0.05 s and 10 min
- Adjustable start time delay 0.6-30 s

Crouzet - Temperature monitoring HT81, HWT81
- Temperature monitoring, lift machinery room per EN81
- Adjustable control between +4 °C and +40 °C
- PT100 input

Crouzet - Translation list, current and level relays